SDA-5500/SDA-5510 Sweep Configuration: Forward Sweep Configuration (SDA-5500)
271
14
Worksheet 2 Output Level Calculation
1. Enter the system level at the sweep
injection point (video carrier level)
2. Subtract the relative level of sweep
points (-15dB recommended)
3. Add the directional coupler (DC) value
4. Add the pad value
Sweep output level
(must be between
+20dBmV and +50dBmV
for high output level
SDA-5500 units)
Worksheet 3 Sweep Level Calculation
1. Enter the system level at the sweep injection
point (video carrier level)
2. Subtract the relative level of sweep points
(-10dB recommended)
3. Add the directional coupler (DC) value
4. Add the pad value
Sweep output level
(must be between
+20dBmV and +50dBmV
for high output level
SDA-5500 units)
Setting Forward Telemetry Levels and Frequencies
The SDA-5500’s forward telemetry signal can be set to any frequency in the
band that is to be swept, providing it is at least 500kHz from any CATV
carrier. Common places for forward telemetry are 52-54MHz, 72-76MHz, in
the FM band, or above the last used channel. The level must be set such
that it is 10 dB below the video carrier level at the SDA-5500 input, and
reads between +12 dBmV and –12 dBmV on the SDA field unit while
sweeping.
Figure 14-4 shows the options provided by the main SWEEP
TRANSCEIVER menu.