Description and Basic Operation of the SDA-5500 and 5510: Global Configuration
224
13
Date: Select this option to enter the date using the numeric entry keys. The
date will be displayed in the format you select in the DATE FORMAT setup
menu.
Printer: The Printer option sets the printer interface to the specific type of
printer used. Use the up and down diamond keys to select the desired
printer. The required serial printer configuration is as follows:
baud rate consistent with SDA-5500 and SDA-5510 (recommend 9600
or 19.2K)
8 data bits
1 stop bit
no parity
flow control - hardware handshaking
A serial to parallel converter (such as the one manufactured by Black Box
Corp.) is required for printing to a parallel printer. The setup is the same as
for the serial printer configuration.
Lines/Page: The number of lines per page (min 30, max 255) can be
specified for text printouts. This determines the number of lines printed
before a form feed command is sent. If no form feeds are desired, enter
zero.
Baud Rate: The baud rate is used when establishing communications
between the SDA-5500 or SDA-5510 and another device. The baud rates
available are 1200, 2400, 4800, 9600, and 19.2k. Use the up and down
diamond keys to set the baud rate.
Beeps: The SDA headend units produce beeps to alert you of certain
operating conditions. Use the diamond keys to turn beeps on or off as
desired.
Diagnostics: Select Diagnostics and press the Enter key to enter the
diagnostic mode. If this option does not appear on the SETUP screen, press
the down arrow until it scrolls onto the list.
From the Diagnostics mode you can perform the following functions:
Default to Factory Settings: When this item is selected and you press the
Enter key, the unit will automatically reset all parameters to the factory
default values.