B-7
Message ERROR... C/N cannot be measured on a scrambled
channel!
Condition A channel that has been
programmed as scrambled in
setup has been selected in C/N
mode.
Response Select a channel that is not
scrambled. C/N measurements are
not possible on a scrambled
channel.
Message ERROR... Hum cannot be measured on a scrambled
channel!
Condition A channel that has been
programmed as scrambled in setup
has been selected in Hum mode.
Response Select a channel that is not
scrambled. Hum measurements are
not possible on a scrambled
channel.
Message SORRY... No more tilt channels can be
programmed.
Condition The maximum number of tilt
channels has been reached.
Response To program another tilt channel, an
existing tilt channel must be
reprogrammed as a non-tilt channel.