User Manual 301/302
output connector. The default SYNC position is the point 0 ( the first
point of the output waveform). The position of the SYNC signal can be
programmed using the OUTPUT:SYNC:POS:POIN command.
The query:
OUTPut:SYNC?
queries the state of the SYNC OUTPUT and returns "0" (OFF) or "1"
(ON).
Using WaveWiz, the SYNC output is turned on and off from the output
tab of the control panel. Check SYNC On to toggle the sync on and
off. See Figure 3.13 below.
Assigning the
Source For The
SYNC Output
The SYNC output generates a synchronized signal at the beginning of
the waveform or at any position on the waveform as may be
programmed by the OUTP:SYNC:POS command. The validation
source for this command is selectable from a number of options. Use
the following command to select the source for validating the SYNC
output:
OUTPut:SYNC:SOURce {BIT | LCOMplete}
BIT Generates a sync signal from the SYNC Output
BNC every time the segment is output in User mode and in
Sequenced mode. The position of the sync output relative to the
waveform can be programmed using the OUTPUT:SYNC:POS
command. The BIT signal is recommended for use in continuous
mode.
LCOMplete Generates a sync signal in SEQ mode only once when
the selected segment appears for the first time in the sequence. The
identity of the segment can be programmed using the TRAC:SEL
command. The sync position along the selected waveform can be
programmed using the OUTPUT:SYNC:POS command. The LCOM
signal is recommended for use in Sequenced mode.
The query:
OUTPut:SYNC:SOURce?
queries the signal source for the SYNC output and returns BIT, or
LCOM.
These modes are selected in WaveWiz by checking the relevant box
in the sync output section (see Figure 3.13 below)