1-23
REFERENCE DISTANCEREFERENCE DISTANCE
REFERENCE DISTANCEREFERENCE DISTANCE
REFERENCE DISTANCE
This is the specified distance at which leakage is to be measured. For
example, in the United States, the FCC requires that all measure-
ments be referenced to 3 meters or 10 feet. If your application
requires a different reference distance, enter it here.
PEAK HOLD RESET PERIODPEAK HOLD RESET PERIOD
PEAK HOLD RESET PERIODPEAK HOLD RESET PERIOD
PEAK HOLD RESET PERIOD
The peak hold feature momentarily holds the peak leakage measure-
ment value. This peak value is displayed numerically and indicated
on the analog meter. This setting allows you to specify how often the
peak hold value is reset. In the Find and Fix mode, the graph scale is
updated to reflect the leakage reading in relation to the new peak
value.
EDIT ANTENNA TYPESEDIT ANTENNA TYPES
EDIT ANTENNA TYPESEDIT ANTENNA TYPES
EDIT ANTENNA TYPES
There are several different types of antennas that you can use with
your CLI-1450 when measuring leakage. Press the key to edit
the antenna factor for each type.
You can edit the antenna factor of the highlighted type by pressing the
key. When the edit box becomes active, enter the desired
value. Be sure to press the key when finished to terminate your
entry.
Press the soft key to return the antenna factor of the highlighted
type to its factory preset value. The factory preset antenna factor for