MODEL MS1300
SPECIFICATIONS
Frequency
Range: 45 to 550 MHz; 45 to 890 MHz (optional);
sub band option (5 to 45 MHz)
Accuracy: +10kHz @ 25°C; (+20 kHz over temp.)
Tuning Resolution: 25 kHz
Level Measurement
Range: -20 to +50 dBmV
Resolution: 0.1 dB
Accuracy: +0.75 dB Flatness; +0.75 dB Linearity
Scan Mode
Number of Channels: 120
Scan Rate: Approximately 6 carriers / second
General
Dimensions: 4.25" (W) x 10" (H) x 2.5" (D)
Weight: 0.8 kg (1.75 lb.)
Operating Temp. Range:-10 to +50°C (14 to 122°F)
Water Resistance: Meets or exceeds MIL-STD-810D
(Method 506.2)